{"product_id":"alorair-sentinel-hd90-90-pint-crawl-space-dehumidifier","title":"AlorAir Sentinel HD90 90-Pint Crawl Space Dehumidifier","description":"\u003cp\u003eThe AlorAir Sentinel HD90 is a gravity-drain crawl space and basement dehumidifier. It removes 90 pints of water a day at AHAM conditions (80°F, 60% RH) and up to 198 pints a day at saturation (90°F, 90% RH), for spaces up to 2,600ft², while drawing 5.56 A.\u003c\/p\u003e\n\u003cp\u003eWith no pump to maintain, it suits installs where a floor drain, sump or outside run sits below the unit. The Sentinel HD90 holds your humidity setpoint on its own humidistat, restarts after power cuts, and can duct dry air into a finished room through its 6\" supply collar.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e90 Pints a Day at AHAM\u003c\/strong\u003e\u003cbr\u003eRemoves 90 pints a day at 80°F and 60% RH, and up to 198 pints at saturation, from 210 CFM of airflow and a rotary compressor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGravity Drainage, No Pump\u003c\/strong\u003e\u003cbr\u003eCondensate runs out through the drain hose by gravity, so there is no pump to clean or replace. The A5\/A6 terminals can take the water level signal from an external condensate pump.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Humidity Control\u003c\/strong\u003e\u003cbr\u003eThe integral humidistat holds any setpoint from 36% to 90%. Below 36%, the unit switches to continuous mode for drying out a wet space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Defrost Down to 33.8°F\u003c\/strong\u003e\u003cbr\u003eAutomatic defrost clears ice from the rare earth alloy tube evaporator, so the unit keeps working in a cool crawl space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Restart\u003c\/strong\u003e\u003cbr\u003eAfter a power cut, the unit comes back on its last setting without anyone going under the house.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDucting and Remote Options\u003c\/strong\u003e\u003cbr\u003eA 6\" supply adapter comes standard, with an optional 12\" return collar. AlorAir's optional wired remote runs on a 25' CAT 5 cable and has its own humidity sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow 5.56 A Draw\u003c\/strong\u003e\u003cbr\u003eRated at 2.69 L\/kWh, it runs on a standard 115 V, 15 A GFCI circuit.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Sentinel HD90\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Removal at AHAM (80°F, 60% RH):\u003c\/strong\u003e 90 pints\/day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Removal at Saturation (90°F, 90% RH):\u003c\/strong\u003e 198 pints\/day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Removal at DOE (60°F, 60% RH):\u003c\/strong\u003e 47.71 pints\/day\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage:\u003c\/strong\u003e Up to 2,600ft²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow:\u003c\/strong\u003e 210 CFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 33.8°F to 104°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity Setpoint Range:\u003c\/strong\u003e 36% to 90%, plus continuous mode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrainage:\u003c\/strong\u003e Gravity drain; A5\/A6 terminals for an optional external condensate pump\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuct Connections:\u003c\/strong\u003e 6\" supply adapter (standard); 12\" return collar (optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 115 V, 60 Hz, 5.56 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Requirement:\u003c\/strong\u003e Grounded 3-prong GFCI outlet, 15 A circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e 2.69 L\/kWh\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressor:\u003c\/strong\u003e Rotary\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter:\u003c\/strong\u003e Washable pre-filter (MERV-8 optional)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e Less than 58 dBA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 23.2\"L x 15.2\"W x 17.7\"H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 67.2 lbs (30.5 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e cETL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlorAir Sentinel HD90 dehumidifier\u003c\/li\u003e\n\u003cli\u003eAir filter (installed)\u003c\/li\u003e\n\u003cli\u003eSupply duct adapter\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSetup \u0026amp; Placement\u003c\/h3\u003e\n\u003cp\u003eSeal the space first: AlorAir specifies a vapor barrier on the ground and sealed vents in a crawl space. Stand the unit level on blocks or pavers, not directly on the vapor barrier, so the condensate can drain. If it was tipped in transit, leave it upright for at least 2 hours before switching on.\u003c\/p\u003e\u003cp\u003eRun the drain line downhill to a drain with no loops or dips, ideally into 3\/4\" PVC at a fall of at least 1\" per 10', and test it before you leave. Allow 12\" of clearance at the inlet and 36\" at the discharge, and plug into a grounded 15 A GFCI circuit.\u003c\/p\u003e\n\u003ch3\u003eResources\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0893\/4037\/9501\/files\/alorair-sentinel-hd90-specification-sheet.pdf?v=1790428442\" target=\"_blank\" rel=\"noopener\"\u003eAlorAir Sentinel HD90 specification sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0893\/4037\/9501\/files\/alorair-sentinel-hd90-installation-operations-manual.pdf?v=1790428447\" target=\"_blank\" rel=\"noopener\"\u003eAlorAir Sentinel HD90 installation and operations manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Shipping\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty.\u003c\/strong\u003e Backed by AlorAir's 12-month limited warranty from the date of delivery, covering defects in materials and workmanship. AlorAir handles warranty service directly, so keep your proof of purchase and the original packaging.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShipping.\u003c\/strong\u003e Ships direct from AlorAir's U.S. warehouse, with free shipping on orders over $100.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInspect on delivery.\u003c\/strong\u003e Check the carton and the unit when it arrives and note any damage on the delivery receipt before signing.\u003c\/p\u003e\n\u003ch3\u003eAbout AlorAir\u003c\/h3\u003e\n\u003cp\u003eAlorAir Solutions is based in Chino, California, and supplies dehumidifiers, air movers and air scrubbers for crawl spaces, basements and water damage restoration. Its Sentinel line is built for permanent installation in the spaces under and around a home.\u003c\/p\u003e\n\u003cp\u003eThe HD90 shares its 90-pint cabinet with the Sentinel HDi90, which adds a built-in condensate pump, and the HDi90 Duct-able Version. For smaller crawl spaces, the Sentinel HDi65S covers up to 1,300ft², while the HDi100 and HDi120 step up to 100 and 120 pints a day at AHAM for larger basements.\u003c\/p\u003e","brand":"AlorAir","offers":[{"title":"Default Title","offer_id":67567973171565,"sku":"RF02ALOS-Sentinel-HD90-0NNMW00","price":1047.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/4037\/9501\/files\/alorair-sentinel-hd90-front-01_83e52265-6095-481d-b975-dc64c0958498.jpg?v=1790465449","url":"https:\/\/mycleansupplies.com\/products\/alorair-sentinel-hd90-90-pint-crawl-space-dehumidifier","provider":"My Clean Supplies","version":"1.0","type":"link"}