AlorAir Sentinel Elite 50X 50-Pint Commercial Dehumidifier with Pump
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
The Sentinel Elite 50X, 60X and 80X use AlorAir's SLGR (super low grain refrigerant) technology in the same 16.14" x 15.15" x 26.85" cabinet, built for garages, basements, gyms, restaurants, warehouses and wine storage. Set humidity anywhere from 35% to 90% RH.
Two large wheels, two foot pads and a pull handle move it between rooms. The power cord wraps on the back, and a latched compartment at the base holds small accessories.
In pump mode, the built-in pump lifts condensate up to 19.6' through the 19.6' hose, so the unit can sit below a sink or window. For gravity drainage, fit the 6.5' hose to the lower outlet and keep its end below that outlet.
Hold the Pump button for 3 seconds to switch modes, and seal the unused outlet with the water plug. A blocked or kinked hose stops the unit with an E4 code until it is cleared.
Choose %RH mode and set 35% to 90% in 1% steps, or switch to GPP mode and set the moisture content from 25 to 200 grains per pound in steps of 5. Continuous mode runs the unit nonstop.
After a power cut, the unit resumes with its setpoint, mode and pump setting once the 3-minute compressor delay has passed, and automatic defrost keeps the coil clear in cool spaces.
Got Questions?
Find answers below or contact our support team.
Yes. In pump mode the built-in pump lifts condensate up to 19.6' through the included 19.6' hose. For a floor drain below the unit, use the 6.5' gravity hose instead.
AlorAir asks you to let the unit stand upright for at least 24 hours after unpacking. It may have been tilted in shipping, and the wait lets the compressor oil settle.
GPP mode controls the unit by the moisture content of the air, in grains per pound, instead of relative humidity. It is useful when temperature swings make relative humidity a misleading target. Set it from 25 to 200 in steps of 5.
AlorAir rates the series from 37.4°F to 100.4°F. It defrosts its coil automatically, and if the room drops to 35.6°F it pauses with an LO code and restarts once the room warms up.
115 V, 60 Hz single phase from a grounded 3-prong GFCI outlet on a 15 A circuit, through an 11.48' cord. Do not use an extension cord or plug adapter.
Unplug the unit and pull the filter out of its slot at the top of the cabinet, then slide in a new one. AlorAir also recommends cleaning the coils once a year with a self-rinsing foaming coil cleaner.