Ninety pints with a built-in pump

The Sentinel HDi90 removes 90 pints of water a day at AHAM conditions (80°F, 60% RH) and up to 198 pints at saturation (90°F, 90% RH), for spaces up to 2,600ft². It does it on a 5.56 A draw, with a rated efficiency of 2.69 L/kWh.

A condensate pump built into the 23.2" x 15.2" x 17.7" cabinet sends the water out through the included drain hose, so the unit does not have to sit above a drain.

Runs only when the air is damp

Runs only when the air is damp

Use the arrow keys to set the humidity target, and the built-in humidistat runs the compressor only when the space is above it. Setting it below the bottom of the range switches the unit to continuous mode for drying out after a leak.

Most crawl spaces are held around 50% to 55% RH. Automatic defrost works down to 33.8°F, and memory restart resumes your settings after a power cut.

Pump drain with a fault alarm

Pump drain with a fault alarm

The integral pump empties its reservoir automatically through a compression fitting on the discharge end. Before moving or storing the unit, press Drain to purge the reservoir; each press runs the pump for 28 seconds.

If the reservoir fills because the pump has stopped, a high water sensor shuts the compressor off and the display shows E4, rather than letting water overflow onto the floor.

Got Questions?

Find answers below or contact our support team.

What happens if the pump fails?

A high water sensor in the pump reservoir stops the compressor and shows an E4 code, and the fan stops a minute later. Check that the pump runs by pressing the Drain button, then unplug the unit for two minutes to reset it. The unit will not run until the code is cleared.

How often does the pump need cleaning?

AlorAir recommends cleaning the pump system at least once a year: drain the reservoir, pour a mild bleach or vinegar solution into the drain tray, let it soak for 15 minutes, then flush the pump with clean water. Dirt and slime in the drain line are the usual cause of pump trouble.

What is the difference between the WiFi and standard versions?

The dehumidifier and pump are the same. The WiFi version adds control and monitoring from the AlorAir-C app, paired by holding the up and down keys together, and a WiFi status light. Its humidity setpoint runs from 35% to 90%, against 36% to 90% on the standard version. Both work with AlorAir's optional wired remote control.

What is the lowest temperature it will run at?

The operating range is 33.8°F to 104°F, with automatic defrost. Outside that range the unit stops and shows LO or HI, so it is not meant for an unheated space that drops below freezing.

Can I duct it into another room?

Yes. The supply side takes 6" flex duct through the standard adapter, and AlorAir sells a 12" return duct collar and a 72" flexible supply duct as accessories. An optional wired remote on a 25' CAT 5 cable lets you read the humidity in the room you are drying.

What power does it need?

115 V, 60 Hz at 5.56 A, on a grounded 3-prong GFCI outlet with a 15 A circuit protector. AlorAir says not to use an extension cord or plug adapter.

Proud to Have Served