AlorAir Sentinel Pro 55X 55-Pint Commercial Dehumidifier with Pump
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
The Sentinel Pro 35X and Pro 55X share one 12.9" x 14.14" x 24.55" cabinet on four 360° wheels, sized for laundry rooms, basements, wine cellars and storage rooms. Set humidity from 25% to 80%, or run it continuously.
A GPP mode controls to moisture content instead of relative humidity, and the touch panel locks so settings stay put in a shared space.
Hold the Drain button for 3 seconds to turn on the built-in pump, which empties the unit through the 19.6' pump hose. For gravity drainage, fit the 6.5' hose to the lower outlet and keep its end below that outlet.
Plug whichever outlet you are not using with the water plug. A kinked or clogged hose stops the unit with an E4 alarm until it is cleared.
When frost forms on the coil in a cool room, the unit defrosts on its own and returns to its previous settings. After a power cut it restarts in the same mode once a 3-minute compressor delay has passed, keeping the setpoint, GPP mode and pump setting.
AlorAir rates both models from 37.4°F to 100.4°F. If the room drops to 35.6°F, the unit pauses with an LO code until it warms up.
Got Questions?
Find answers below or contact our support team.
Unplug the unit and pull the MERV-1 filter out of the air intake grille at the back. Vacuum it or rinse it in warm water with no cleaning agents, and let it air dry in the shade before refitting.
GPP mode runs the unit to a moisture content target in grains per pound, set from 25 to 200 in steps of 5, instead of a relative humidity target. The display then shows moisture content.
Yes. Hold the Lock button for 3 seconds. All buttons except Lock and Power stop responding until you hold Lock again. The lock is not kept after a power cut.
115 V, 60 Hz single phase from a grounded 3-prong GFCI outlet on a 15 A circuit. AlorAir advises against extension cords and plug adapters.
In a closed room, ideally near the center, standing upright on the floor with the inlet and outlet clear of walls. Close windows while it runs.
Occasionally. With the unit drained and unplugged, remove the two screws below the left air outlet, slide the handle down, and rinse the pump filter, float switch and drip tray with water before reassembling.