AlorAir Storm Pro 85-Pint Commercial Dehumidifier with Pump
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
The Storm Pro removes 85 pints a day at AHAM conditions (80°F, 60% RH) and up to 180 pints a day at saturation (90°F, 90% RH), moving 210 CFM on 5.6 A. AlorAir rates it for spaces up to 2,300ft² at 2.88 L/kWh.
The upright 21.2" x 22" x 38" rotomolded body weighs 99.2 lbs and rolls on two large-diameter wheels with a rigid handle.
The built-in condensate pump drains the unit through the included hose, which fits a quick connection on the base, and the drain line can rise up to 15' before it reaches the final drain. The pump itself unplugs on quick connectors for service.
AlorAir recommends cleaning the pump reservoir and lines at least once a year with a mild bleach or vinegar solution. An E4 code on the display means the pump needs attention.
Every Storm Pro connects to the AlorAir app, directly or through a WiFi network, so you can follow a drying job without going back to site. On the unit, the LCD shows temperature, humidity and grains per pound (GPP) at the inlet and outlet, with job and lifetime hours.
Set humidity from 25% to 80% in 5% steps, or continuous mode. After a power cut, the unit restarts on its last settings.
Got Questions?
Find answers below or contact our support team.
85 pints a day at AHAM conditions (80°F, 60% RH) and up to 180 pints a day at saturation (90°F, 90% RH). AlorAir rates it for spaces up to 2,300ft².
All four. Green, red, yellow and blue Storm Pro units connect to the AlorAir app, directly or over WiFi, and also run from the LCD panel on the unit.
Yes. The discharge takes 6" flex or lay-flat duct, so you can condition an adjacent room or aim dry air at one area.
AlorAir rates it from 33.8°F to 105°F, with automatic defrost. Below 33.8°F the unit stops and shows LO until the space warms up.
115 V, 60 Hz single phase from a grounded 3-prong GFI outlet, protected by a 15 A time-delay fuse or breaker. It draws 5.6 A through an 18' cord. Do not use an extension cord or plug adapter.
Wash the pre-filter in warm water or vacuum it, with no soap, and let it dry. Replace the MERV-8 filter as needed; AlorAir recommends checking it at least once a year.
Proud to Have Served
















































{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}