This series removes 125 pints a day at AHAM conditions (80°F, 60% RH) from a 300 CFM airflow while drawing 8.1 A, and AlorAir rates it for spaces up to 3,000ft². Its low grain refrigerant (LGR) design is built to keep drying as the air gets drier late in a job.
At 26.1" x 15.5" x 17.6" and 79.2 lbs, it rolls on two wheels with a telescopic handle, and the shell is shaped so units stack for storage and transport.
The large LCD reports temperature, relative humidity and grains per pound (GPP) at the inlet and the outlet, so the difference between the two tells you how hard the unit is working. Job hours clear between sites and lifetime hours keep counting.
Choose a setpoint from 25% to 80% in 5% steps, or continuous mode to run nonstop. The display switches between °F and °C and between lb and kg moisture units.
A built-in condensate pump pushes water out through the included drain hose, which attaches with a quick connector, so the unit can run overnight with nothing to empty. Keep the hose outlet no higher than 15' and uncoil it fully before use.
Press Purge before you unplug or move the unit so the reservoir is empty. If the pump has a problem, the display shows an E4 code.
Got Questions?
Find answers below or contact our support team.
125 pints a day at AHAM conditions (80°F, 60% RH), with a 300 CFM airflow. AlorAir rates the SLGR 1250X for spaces up to 3,000ft². Output in the field depends on the temperature and humidity of the space.
They share the same body, the same 125-pint AHAM rating, the same 8.1 A draw and a built-in pump. The LGR 1250X adds WiFi control through the AlorAir app. The SLGR 1250X is app-controlled too and adds AlorAir's SLGR precooling circuit: an auxiliary refrigerant path with its own expansion device feeds a microchannel precooler that chills incoming air toward its dew point before the evaporator.
It draws 8.1 A on 115 V and needs a grounded 3-prong GFCI outlet on a 15 A circuit. Check the total draw of anything else on that circuit, and do not use an extension cord or plug adapter.
AlorAir says never to place the end of the hose higher than 15'. Run it to a sink, floor drain or outside, and check it is not kinked before starting.
The operating range is 33.8°F to 110°F. The unit defrosts its coil automatically, but below 33.8°F it stops and shows LO, and above 110°F it stops and shows HI until the temperature is back in range.
79.2 lbs. It rolls on two wheels with a telescopic handle, and the body is shaped so several units stack for storage and transport.