AlorAir VentirPro-S2 Dual-Fan Crawl Space Ventilation Fan, 240 CFM
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
The VentirPro-S2 exhausts up to 240 CFM through a foundation vent using two DC fans on double ball bearing motors, which AlorAir rates for more than 65,000 hours of running time. A low 1.7" profile keeps it tight to the wall.
It runs from a plug-in adapter rated 110 V to 230 V, drawing a rated 8.5 W. AlorAir rates it for crawl spaces and basements up to about 450ft².
The LCD controller reads the included temperature and humidity probe. Set a humidity level (1% to 99%) and a temperature (37°F to 176°F), and the fans run when the space is above either one. Five fan speeds and a run and rest time cycle let you ventilate on a schedule.
Unplug the probe to switch to continuous operation.
The probe plugs into the bottom of the fan unit and should sit in the same space as the fan, away from anything that could wet or damage it. The controller alarms and shows dashes if the probe reading is lost.
If condensation fogs the display in a very humid space, switch the fan off until it clears.
Got Questions?
Find answers below or contact our support team.
This model is the air-out version: it exhausts damp air from the crawl space through the foundation vent.
Unplug the temperature and humidity probe. The display shows dashes and the unit switches to continuous operation.
It runs from the included plug-in adapter, rated 110 V to 230 V at 50/60 Hz, which powers the 12 V DC fans.
AlorAir lists up to 48 dBA, depending on the fan speed you choose.
AlorAir states it should be installed by a qualified installer to local codes. It mounts over the vent with four screws and plugs into a nearby outlet.