AlorAir X-Force Wall Cavity Drying System with Air Mover Blower
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
Product support & personalised quotes
Monday to Friday 9:00AM to 5:00PM EST
The X-Force works in two modes. Connected to the intake, it pulls moist air out of wall and ceiling cavities under negative pressure. Moved to the outlet, it drives dry air into the cavities under positive pressure.
AlorAir's procedure runs extraction until the treated area reads as dry as the untreated area, then switches to injection with the silencer filter fitted to finish the job.
Each manifold feeds 12 supply lines with a nozzle on each. AlorAir plans one manifold for about every 5' of 2x4 interior wall, and one per 7' on 2x6 exterior, fire-rated or dense walls, which typically gives 25 to 30 air changes an hour.
A T fitting splits the air delivery hose in two directions, which moves more air than a single run and can reach two rooms at once.
Got Questions?
Find answers below or contact our support team.
No. AlorAir says the system is for moving air only, not for removing water or debris. Extract standing water first, then use the X-Force to dry the cavities.
Less than 1/4". AlorAir suggests a carpet awl or a drill with a 3/16" bit, placed about 2" above the floor and below the top of the baseboard, so the holes are easy to patch.
Never into occupied rooms. Run the exhaust outside through a hose, or fit a HEPA filtration attachment (an accessory), so moisture and contaminants from the cavities stay out of the living space.
A standard 115 V grounded receptacle with GFCI protection. Do not use it with solid-state speed controls or ungrounded extension cords.
Proud to Have Served
















































{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}