Room air passes a washable blue pre-filter and then a steel-cased HEPA filter, 21" x 13.5" x 4", before it reaches the coil. KwiKool rates the HEPA filter to remove 99.9% of particles of 0.3 µm and larger, so the room is cooled and filtered in one pass.
Plan on replacing the HEPA filter about twice a year, sooner in dusty spaces. Washing the pre-filter regularly protects the HEPA filter and keeps the airflow up.
Ultraviolet germicidal lamps inside the cabinet expose the air chamber and the filter to UVC energy at 253.7 nanometers. UVC light inactivates microorganisms such as bacteria and mold spores by damaging their DNA so they cannot replicate.
The lamps sit inside the 304 stainless cabinet, and the control's filter counter raises an alert when the filter run time has elapsed.
The BioKool's I/O integral condenser ducts both the condenser make-up air and the discharge air, so it runs without pulling the cooled room into negative pressure. KwiKool's two-duct ceiling kit uses two 8' ducts and flanges with foam tape to connect both openings to the ceiling.
The stainless CK-12SS ceiling kit is sold separately. Ducting both openings keeps the full rated capacity in the room, which matters in clean spaces such as clinics and labs.
Got Questions?
Find answers below or contact our support team.
Both are 13,800 BTU/hr BioKool spot coolers with HEPA filtration and UVC lamps. The KBIX1411-3 adds needle-point bipolar ionization. Cooling, electrical data, size and weight are the same.
It runs on 115V single-phase and draws 15.8 A. KwiKool specifies a 20 A breaker and a NEMA 5-20 receptacle for the factory plug. Do not cut or change the plug, because that voids the warranty.
The BioKool comes standard with an external 5-gallon condensate tank. A float switch stops the unit and sounds an alarm when the tank is full, and the alarm clears when the tank is emptied and reconnected. You can also route the condensate to a drain.
KwiKool says to expect to replace the HEPA filter (part 14-FILTERBIO) about twice a year, depending on air quality. The blue pre-filter is washable: blow it out or rinse it, and let it dry fully before you reinstall it.
No. KwiKool designs its portable cooling systems for commercial and industrial use, and the warranty covers commercial and industrial purchasers. Typical sites are clinics, labs, offices and equipment rooms.