The MRCOOL Olympus E Star single-zone ductless mini-split heat pump system pairs an inverter condenser with a matching Olympus wall-mount air handler to heat and cool one room or open area. It runs on R-454B refrigerant from 9,000 to 24,000 BTU/h, reaches up to 27.4 SEER2 on the 9,000 BTU pair, and is rated to operate in outdoor temperatures down to -22°F.
It suits a garage, addition, sunroom or bedroom in a cold climate where ducts are impractical. Installation is by a licensed HVAC contractor.
Features
Matched Condenser and Wall Head
Each system pairs an O-ES condenser with the Olympus wall-mount air handler of the same capacity, for example O-ES-12-HP-C-230C-O1 with O-12-HP-WMAH-230C-O.
High Efficiency
Up to 27.4 SEER2 and 12.5 HSPF2 in Region IV on the 9,000 BTU size, with ENERGY STAR ratings across all four sizes.
Cold-Climate Heating
Rated to heat in outdoor air down to -22°F; the 24,000 BTU pair delivers 24,200 BTU/h at 5°F.
Quiet Indoor Unit
The wall head runs as low as 16 dBA on the 24,000 BTU size and 19.5 dBA on the smaller sizes, with fan speed adjustable from 1% to 100%.
App, Voice and Remote Control
A Smart Controller Kit connects the head to the MRCOOL SmartHVAC app, Amazon Alexa and Google Assistant, and the remote's Follow Me function senses the temperature where you are.
Refrigerant Leak Detection
An A2L sensor in the indoor unit shows an error code if it detects an R-454B leak.
Gold Fin Condenser Coil
The outdoor coil carries MRCOOL's Gold Fin coating to resist corrosion, which suits coastal homes.
Specifications
-
Voltage: 208/230V
-
Phase: 1
-
Frequency: 60 Hz
-
Refrigerant: R-454B
-
Compressor: Rotary
-
Inverter: DC
-
ENERGY STAR: Yes
-
AHRI Certified: Yes
-
UL Listed: Yes
-
ETL Listed: Yes
-
CSA Listed: Yes
-
Color: White
9,000 BTU 230V
-
Model: O-ES-09-HP-230C-O1
-
Cooling Capacity: 9,000 BTU/h
-
Heating Capacity: 12,000 BTU/h
-
Nominal Tonnage: 0.75 ton
-
SEER2: Up to 27.4
-
EER2: Up to 15.4
-
HSPF2 (Region IV): 12.5
-
HSPF2 (Region V): 9.5
-
Coverage Area: Up to 400 ft²
-
Minimum Circuit Ampacity: 15 A
-
Max Fuse / Breaker: 15 A
-
Refrigerant Charge: 35.27 oz
-
Sound Level: 56 dBA
-
Max Line Set Length: 82'
-
Liquid Line: 1/4"
-
Suction Line: 3/8"
-
Metering Device: EXV
-
Works With: O-09-HP-WMAH-230C-O
DUCT-09HP-230B-O
CASSETTE09HP-230C-O
-
Outdoor Unit Dimensions: 31.69"W x 12.99"D x 21.81"H
-
Outdoor Unit Weight: 72.75 lbs
12,000 BTU 230V
-
Model: O-ES-12-HP-230C-O1
-
Cooling Capacity: 12,000 BTU/h
-
Heating Capacity: 12,000 BTU/h
-
Nominal Tonnage: 1 ton
-
SEER2: Up to 25.4
-
EER2: Up to 13.4
-
HSPF2 (Region IV): 10.5
-
HSPF2 (Region V): 8
-
Coverage Area: Up to 550 ft²
-
Minimum Circuit Ampacity: 15 A
-
Max Fuse / Breaker: 15 A
-
Refrigerant Charge: 35.27 oz
-
Sound Level: 56 dBA
-
Max Line Set Length: 82'
-
Liquid Line: 1/4"
-
Suction Line: 3/8"
-
Metering Device: EXV
-
Works With: O-12-HP-WMAH-230C-O
DUCT-12HP-230B-O
CASSETTE12HP-230C-O
-
Outdoor Unit Dimensions: 31.69"W x 12.99"D x 21.81"H
-
Outdoor Unit Weight: 72.75 lbs
18,000 BTU 230V
-
Model: O-ES-18-HP-230C-O1
-
Cooling Capacity: 18,000 BTU/h
-
Heating Capacity: 18,000 BTU/h
-
Nominal Tonnage: 1.5 ton
-
SEER2: Up to 21.4
-
EER2: Up to 12.5
-
HSPF2 (Region IV): 11
-
HSPF2 (Region V): 8.5
-
Minimum Circuit Ampacity: 19 A
-
Max Fuse / Breaker: 20 A
-
Refrigerant Charge: 55.38 oz
-
Sound Level: 59 dBA
-
Max Line Set Length: 98.4'
-
Liquid Line: 1/4"
-
Suction Line: 1/2"
-
Metering Device: EXV + Throttle Valve
-
Works With: O-18-HP-WMAH-230C-O
DUCT-18HP-230B-O
CASSETTE18HP-230C-O
-
Outdoor Unit Dimensions: 35.04"W x 13.46"D x 26.5"H
-
Outdoor Unit Weight: 99.87 lbs
-
Coverage Area: Up to 800 ft²
24,000 BTU 230V
-
Model: O-ES-24-HP-230C-O1
-
Cooling Capacity: 24,000 BTU/h
-
Heating Capacity: 29,000 BTU/h
-
Nominal Tonnage: 2 ton
-
SEER2: Up to 21
-
EER2: Up to 13
-
HSPF2 (Region IV): 13.5
-
HSPF2 (Region V): 9.8
-
Coverage Area: Up to 1,050 ft²
-
Minimum Circuit Ampacity: 24.9 A
-
Max Fuse / Breaker: 25 A
-
Refrigerant Charge: 63.49 oz
-
Sound Level: 61.5 dBA
-
Max Line Set Length: 164'
-
Liquid Line: 3/8"
-
Suction Line: 5/8"
-
Metering Device: EXV + Throttle Valve
-
Works With: O-24-HP-WMAH-230C-O
DUCT-24HP-230B-O
CASSETTE24HP-230C-O
-
Outdoor Unit Dimensions: 37.24"W x 16.14"D x 31.89"H
-
Outdoor Unit Weight: 130.29 lbs
What's Included
- MRCOOL Olympus E Star outdoor condenser in the selected capacity
- MRCOOL Olympus wall-mount air handler in the matching capacity
- Metal mounting plate and cardboard template, anchors and fixing screws
- Remote control with holder, screws and AAA batteries
- Smart Controller Kit (Wi-Fi module)
- Drain joint, seal, copper nuts and small filter
- Installation and remote control manuals
Installation
Professional installation required. This equipment must be installed by a licensed HVAC contractor (EPA Section 608-certified for any refrigerant work), following MRCOOL's installation manual and all local codes, permits and licensing rules. MRCOOL's limited warranty applies only to units installed that way, and it does not cover installation labor.
Line sets are not included. Line sizes are 1/4" x 3/8" (9,000 and 12,000 BTU), 1/4" x 1/2" (18,000 BTU) or 3/8" x 5/8" (24,000 BTU). The factory charge covers 24.6' of line, with a maximum length of 82' (9,000 and 12,000 BTU), 98.4' (18,000 BTU) or 164' (24,000 BTU) and a maximum height difference of 49.2', 65.6' and 82' respectively. Where the suction line is 5/8", the wall hole should be 3-1/2" across. The condenser takes a 208/230V single-phase supply; circuit sizes are in the Specifications tab.
Resources
Shipping, Returns & Warranty
Ships to addresses in the United States only. Shipping cost is calculated at checkout.
Inspect the packaging and the product before you sign. Note any damage or shortage on the delivery receipt, then email photos to support@mycleansupplies.com within 48 hours of delivery so the freight claim can be filed. Damage reported after 48 hours can't be claimed.
MRCOOL handles returns through the store you bought from, so your return comes to us. Unopened, unused MRCOOL equipment can be returned within 21 days of delivery with a return authorization from us. You pay the return shipping, and a restocking fee of up to 20% may be deducted along with payment processing fees. Opened, installed or used equipment and special-order items can't be returned.
MRCOOL's Olympus limited warranty covers parts for 5 years and the compressor for 7 years from the proof-of-purchase date, with no registration required. It applies to systems installed according to MRCOOL's instructions and all applicable codes and permits, and it does not cover labor. Full terms, registration steps and exclusions are in the MRCOOL warranty document under Resources.
Warranty claims. MRCOOL handles warranty claims directly through support.mrcool.com or (270) 366-0457. Some MRCOOL warranties cover the original purchaser only. Systems that aren't DIY need a valid installation invoice to open a claim.
About MRCOOL
MRCOOL designs heating, cooling and water-heating equipment from its home base in Hickory, Kentucky. The range runs from DIY ductless mini-splits, built around MRCOOL's patented pre-charged Quick Connect line sets, through contractor-installed mini-splits, central split systems, packaged units and gas furnaces, to HeatWise water heaters and CoolBlade HVLS fans for warehouses and shops.
Olympus E Star is MRCOOL's contractor-installed single-zone ductless heat pump on R-454B refrigerant, with ENERGY STAR ratings in all four sizes from 9,000 to 24,000 BTU/h. Each O-ES condenser serves one Olympus indoor unit of the same capacity: the wall-mount air handler it is sold with as a system, or an Olympus ceiling cassette or concealed ducted air handler bought separately. For several rooms on one outdoor unit, MRCOOL offers the Olympus Multi-Zone condensers, which use the same indoor heads.