Enter the air temperature and either relative humidity or dew point to get grains per pound (GPP), dew point and vapor pressure. Tick the second reading to compare two spots, such as the air going into a dehumidifier and the air coming out.
29.92 inHg is the standard atmosphere at sea level. Use the station pressure (not the sea-level-corrected number) where you are; thinner air holds more grains at the same RH.
Reading 1
54.5 grains per pound
Reading 2
Results come from the National Weather Service formulas below and can differ slightly from a printed psychrometric chart, which uses fuller equations. For daily drying logs, keep using the same method so the readings compare.
Relative humidity alone does not tell you how much water is in the air, because warm air holds more. Grains per pound does: it is the weight of water vapor in a pound of dry air, with 7,000 grains to the pound. The calculator works it out in these steps:
es = 6.11 × 10^(7.5 × T ÷ (237.3 + T)) saturation vapor pressure, hPa, T in °C
e = es × RH ÷ 100 actual vapor pressure
w = 621.97 × e ÷ (P - e) grams of water per kilogram of dry air
GPP = w × 7 (7,000 grains per pound ÷ 1,000)
Dew point = 237.3 × L ÷ (7.5 - L), where L = log10(e ÷ 6.11)
Example: 70°F and 50% RH at sea level comes to about 54.5 grains per pound, with a dew point of about 50.5°F.
Comparing two readings gives the difference in grains between them. Restorers call the difference between the air entering a dehumidifier and the air leaving it the grain depression; at the same airflow, a bigger difference means more water removed.
| Temp | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% |
|---|---|---|---|---|---|---|---|---|
| 60°F | 15 | 23 | 31 | 38 | 46 | 54 | 62 | 69 |
| 65°F | 18 | 27 | 37 | 46 | 55 | 64 | 74 | 83 |
| 70°F | 22 | 33 | 43 | 54 | 66 | 77 | 88 | 99 |
| 75°F | 26 | 39 | 52 | 65 | 78 | 91 | 104 | 118 |
| 80°F | 30 | 46 | 61 | 76 | 92 | 108 | 124 | 140 |
| 85°F | 36 | 54 | 72 | 90 | 109 | 127 | 146 | 165 |
| 90°F | 42 | 63 | 84 | 106 | 128 | 150 | 172 | 195 |
| 95°F | 49 | 74 | 99 | 124 | 150 | 176 | 202 | 229 |
| 100°F | 57 | 86 | 116 | 145 | 176 | 206 | 237 | 269 |
National Weather Service, Vapor Pressure and Mixing Ratio calculation sheets. NIST Special Publication 811, Appendix B.9: grain, pound, inch of mercury and standard atmosphere.
$74.99
Shows temperature and 10% to 90% RH on one screen.
View product : Extech 445580 Compact Digital Hygro-Thermometer 14 to 122°F$217.79
Hygro-thermometer with an infrared thermometer for surface temperatures.
View product : Extech RH101 Hygro-Thermometer & Infrared Thermometer, -58 to 932°F, 8:1, Humidity Air Temp$1,609.00
Moisture meter, thermal camera and hygrometer in one, rated ±2.5% RH.
View product : FLIR MR277 Moisture Meter with MSX Infrared Camera and Hygrometer for Building InspectionsFrom $799.11
LGR dehumidifier, 85 pints AHAM and 180 at saturation.
View product : AlorAir Storm LGR Extreme 85-Pint Commercial Dehumidifier with PumpIt is the weight of water vapor in one pound of dry air, counted in grains (7,000 grains make a pound). Unlike relative humidity, it does not change when the air warms up or cools down without gaining or losing water.
Find the actual vapor pressure from the temperature and RH, then solve the National Weather Service vapor pressure formula for temperature. At 70°F and 50% RH the dew point is about 50.5°F.
It shows whether the air is actually getting drier. Relative humidity changes whenever the temperature changes, but GPP only falls when water vapor leaves the air, so it is the steadier number to log day to day.
Yes, a little. Lower air pressure means more grains per pound at the same temperature and RH. Open the air pressure setting and enter your station pressure; 29.92 inHg is sea level.
CFM and the number of air scrubbers for a room.
OpenPints per day for a basement, crawl space or water job.
OpenConvert Pa and in WC, with containment targets.
OpenHow many air movers a wet room needs.
Open3M pad colors by job and machine speed.
Open